				 Posted: Mon Feb 23, 2009 6:49 am    Post subject: Data source not found, confused about 32 and 64 bit eg's | 
				     | 
			   
			 
		   | 
		
		
		   Novice
 
 Joined: 02 Jan 2006 Posts: 12
  
  | 
		  
		    
			  
				Environment is Solaris 10, WMB 6.102 and Oracle 10.
 
 
First I set up a test environment. Created an execution group selecting processor architecture "default". Set up the data source for the message flow in odbc.ini selecting 64-bit drivers and setting up tnsnames.ora. I also have an .odbc32.ini. The broker db is specified on both odbc.ini files.
 
 
Next on to the production environment. Same sw levels same procedure but it didn't work. I got the following error.
 
 
 Database error: SQL State '
 
IM002'; Native Error Code '0'; Error Text '[DataDirect][ODBC lib] Data source name not found and no default driver specified'.
 
 
To get it to work I set up the message flow data source in the odbc32.ini also.
 
 
This makes me confused since I thought by selecting processor architecture "default" I would get an 64bit eg. Am I wrong?
 
 
Maybe it's bad practice to not specify exactly what architure to use but still. | 
			   
			 
		   | 
		
		
		  | Back to top | 
		  
		  	
		   | 
		
		
		    | 
		
		
		  | sridhsri | 
		  
		    
			  
				 Posted: Mon Feb 23, 2009 9:37 am    Post subject:  | 
				     | 
			   
			 
		   | 
		
		
		   Master
 
 Joined: 19 Jun 2008 Posts: 297
  
  | 
		  
		    
			  
				You are right - the default is 64 bit.
 
 
It depends on which variable is set ODBCINI or ODBCINI32 ? ODBCINI points to 64 bit DS. | 
			   
			 
		   | 
		
		
		  | Back to top | 
		  
		  	
		   | 
		
		
		    | 
		
		
		  | Koit | 
		  
		    
			  
				 Posted: Mon Feb 23, 2009 10:54 pm    Post subject:  | 
				     | 
			   
			 
		   | 
		
		
		   Novice
 
 Joined: 02 Jan 2006 Posts: 12
  
  | 
		  
		    
			  
				| Does anyone have an idea why I had to set up an odbc32.ini in my case? | 
			   
			 
		   | 
		
		
		  | Back to top | 
		  
		  	
		   | 
		
		
		    | 
		
		
		  | mqjeff | 
		  
		    
			  
				 Posted: Tue Feb 24, 2009 5:04 am    Post subject:  | 
				     | 
			   
			 
		   | 
		
		
		   Grand Master
 
 Joined: 25 Jun 2008 Posts: 17447
  
  | 
		  
		    
			  
				| There's a matrix in the Broker Info Center that tells you when you need to configure which odbc file. | 
			   
			 
		   | 
		
		
		  | Back to top | 
		  
		  	
		   | 
		
		
		    | 
		
		
		  | Koit | 
		  
		    
			  
				 Posted: Tue Feb 24, 2009 5:17 am    Post subject:  | 
				     | 
			   
			 
		   | 
		
		
		   Novice
 
 Joined: 02 Jan 2006 Posts: 12
  
  | 
		  
		    
			  
				According to the matrix I should only need a 64-bit odbc connection when I am running Solaris 10, Oracle 10, WMB 6.1, MQ 6 and create an eg with processor architecture "default".
 
 
My conclusion is that there is a factor that I don't understand that makes my default eg's 32-bit which I don't like since it's different in my test environment. | 
			   
			 
		   | 
		
		
		  | Back to top | 
		  
		  	
		   | 
		
		
		    | 
		
		
		  | paranoid221 | 
		  
		    
			  
				 Posted: Fri Feb 27, 2009 3:03 am    Post subject:  | 
				     | 
			   
			 
		   | 
		
		
		    Centurion
 
 Joined: 03 Apr 2006 Posts: 101 Location: USA 
  | 
		  
		    
			  
				Hmmm .. probably because broker runtime is a 32-bit vm and is causing your EGs also to inherit the same..    
 
Just thinking out loud here. Pardon my ignorance if I'm wrong   _________________ LIFE is a series of complex calculations, somewhere multiplied by ZERO. | 
			   
			 
		   | 
		
		
		  | Back to top | 
		  
		  	
		   | 
		
		
		    | 
		
		
		  | chids | 
		  
		    
			  
				 Posted: Fri Feb 27, 2009 5:59 am    Post subject:  | 
				     | 
			   
			 
		   | 
		
		
		    Novice
 
 Joined: 09 Oct 2006 Posts: 22 Location: Stockholm, Sweden 
  | 
		  
		    
			  
				
   
	| Koit wrote: | 
   
  
	According to the matrix I should only need a 64-bit odbc connection when I am running Solaris 10, Oracle 10, WMB 6.1, MQ 6 and create an eg with processor architecture "default".
 
 
My conclusion is that there is a factor that I don't understand that makes my default eg's 32-bit which I don't like since it's different in my test environment. | 
   
 
 
 
So it this only a problem with the default EGs? I'd assume you're not interested in the default EGs anyway you should probably scrap those and then create the EGs you need to be 64-bit.
 
 
Could this be the cause of an earlier WMBv6.0 enivronment? WMBv6.0 was not 64-bit pure and thus would require a 32-bit configuration for the WMB-internal DB-connections whereas a 64-bit EG obviously would utilize the 64-bit config.  Reading through our company internal knowledge base I came across a page I wrote on the topic in November 2008. Relevant parts are:
 
 
In v6.1 using 64-bit execution groups would mean everything would be 64-bit so no 32-bit ODBC datasources would be required.
 
 
If you were to go full 32-bit in v6.0 then when migrating to v6.1 you would either require a 32+64 mix to keep the 32-bit execution group operating, or you would have to move to 64-bit execution groups at this point.
 
 
On all platforms except HP-UX (Integrity platform), parts of the broker need 32-bit access to the data source. You must therefore always define a 32-bit ODBC data source name (DSN) for the broker to connect to the broker database; this is true even if the broker has a 64-bit database, in which case you must present the broker with an environment that provides a 32 bit-compatible interface to the database (see Setting your environment to access databases). _________________ /mårten.
 
-- http://marten.gustafson.pp.se/
 