Better yet, now that you stopped using inetd, make the Listener an object that the QM owns. This way the QM starts and stops the Listener automagically and you can simplify your MQ start/stop scripts.
Pls rem to add control(qmgr) in your def eg.
define listener(QMGR.TCP) TRPTYPE(TCP) PORT (PORT) CONTROL(QMGR)
If you leave the control attribute, the default is manual. if you are using explorer to create the listener, choose 'queue manager' from the dropdown.