| Author | 
		  Message | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Sun Nov 28, 2010 12:04 am   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  | The scripts are the same, because the scripts holds in switch disks | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Fri Nov 26, 2010 6:50 am   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  | Nobody  tamper with the SYSTEM.CHANNEL.SYNC.QUEUE | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Fri Nov 26, 2010 12:52 am   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  Yes, I don't mean delete  and redefine a new recv channel object, I mean stop and restart recv channel.
 
 The sequence number is "persistent", is it?
 Why did the recv channel lost its befo ... | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Thu Nov 25, 2010 6:20 pm   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  | SDR channel isn't out of sync. When failover from A node to B node, it's fine. But when failover from B node to A node, only RCV channel does report out-of-sequence error. And failover scripts is the  ... | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Wed Nov 24, 2010 5:25 pm   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  Nobody reset the receiver channel, and HA switch scripts is following:
 endmqlsr -m qmgr-name
 endmqm -w qmgr-name
 
 When the disk switch to another node, run the scripts:
 strmqm qmgr-name
 runmqlsr ... | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Wed Nov 24, 2010 12:01 am   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  Thanks for your reply.
 Yes, qmgr is the same on the second server, namely failover switch the disks with hold the qmgr data.
 I know to resolve seqno mismatch with reset channel. I want to find out t ... | 
  		
  		
		     Topic: Issue with message sequence number after HA switched | 
  		
  		
		  jordanfang
  
	  	  Replies: 17 Views: 20218
  | 
		   Forum: General IBM MQ Support   Posted: Tue Nov 23, 2010 7:21 pm   Subject: Issue with message sequence number after HA switched | 
  		
  		
		  Hi, all
 
     We are using MQ 5.3 on HP-UX.
     There is a qmgr with hardwre failover, which communicates with an external qmgr. After HA switched, our reciever channel  ended abnormally, error mess ... |