Posted: Tue Sep 20, 2016 12:32 pm Post subject: DataPower Secure Gateway Client help
Newbie
Joined: 18 Oct 2013 Posts: 7
I'm trying to integrate Bluemix Secure Gateway with on premise DataPower appliance. I explored the option of using the secure gateway client (as we are on 7.5.1 DataPower firmware). The secure gateway client configuration appears to be a simple object with client name, Gateway Id, Token, ACL for Destinations.
Q1. How do we terminate SSL on the DataPower appliance and start a new SSL session?
Q2. How do we enforce AAA policy?
Q3. Is there a way where I can reference the secure gateway client within an MPG or I can’t use MPGs?
Joined: 04 Sep 2012 Posts: 77 Location: UK beyond the meadows of RocknRoll
Q1. How do we terminate SSL on the DataPower appliance and start a new SSL session?
The only way is to use SSL Proxy which is accessed via the Secure Gateway.
Q2. How do we enforce AAA policy?
Not directly in Secure Gateway client but if an MPGW is attached to either a SSL Proxy or TCP Proxy which is then accessed via SG client.
Q3. Is there a way where I can reference the secure gateway client within an MPG or I can’t use MPGs?
No direct reference and has to be done as stated above. _________________ A Colorblind man may appear disadvantaged but he always sees more than just colors...